from pytest import approx, raises
from openmc.data import mass_energy_absorption_coefficient, mass_attenuation_coefficient
from openmc.data.function import Tabulated1D
def test_mass_attenuation_type():
mu = mass_attenuation_coefficient(26) # Fe
assert isinstance(mu, Tabulated1D)
def test_mass_attenuation_spot_values():
# Spot checks for Fe (Z=26) against NIST data: first/last tabulated points
# and a mid-range value at 1 MeV
mu = mass_attenuation_coefficient(26)
assert mu(1e3) == approx(9085.0)
assert mu(1e6) == approx(0.05995)
assert mu(2e7) == approx(0.03224)
def test_mass_attenuation_caching():
# Repeated calls with the same Z should return the identical object
mu1 = mass_attenuation_coefficient(26)
mu2 = mass_attenuation_coefficient('Fe')
assert mu1 is mu2
def test_mass_attenuation_invalid_z():
with raises(ValueError, match="Z=0"):
mass_attenuation_coefficient(0)
with raises(ValueError, match="Z=200"):
mass_attenuation_coefficient(200)
def test_mass_energy_absorption_type():
# Spot checks on values from NIST tables
mu_en = mass_energy_absorption_coefficient("air")
assert isinstance(mu_en, Tabulated1D)
def test_mass_energy_absorption_spot_values():
mu_en = mass_energy_absorption_coefficient("air")
assert mu_en(1e3) == approx(3.599e3)
assert mu_en(10.e3) == approx(4.742)
assert mu_en(2e7) == approx(1.311e-2)
def test_mass_energy_absorption_invalid():
# Invalid material/data_source should raise an exception
with raises(ValueError):
mass_energy_absorption_coefficient("pasta")
with raises(ValueError):
mass_energy_absorption_coefficient("air", data_source="nist000")