# Molecular Dynamics
|
|
|
|
Molecular dynamics (MD) simulates how atoms and molecules move in time. It is widely used to sample
|
|
finite-temperature behaviour, compute thermodynamic averages, and analyse dynamical properties such
|
|
as diffusion, vibrations, structural fluctuations, and reaction events. MD trajectories are also a
|
|
common starting point for more advanced simulation and analysis techniques.
|
|
|
|
In CP2K, the forces used for MD are provided by a selected `FORCE_EVAL` method. The same MD driver
|
|
can therefore be used with classical force fields, machine-learning potentials, QM/MM,
|
|
semi-empirical methods, and Born-Oppenheimer ab-initio molecular dynamics (AIMD).
|
|
|
|
```{youtube} cGDiVSWpXLc
|
|
---
|
|
url_parameters: ?start=2
|
|
align: center
|
|
privacy_mode:
|
|
---
|
|
```
|
|
|
|
## Basic setup
|
|
|
|
Select an MD calculation with [`RUN_TYPE MD`](#CP2K_INPUT.GLOBAL.RUN_TYPE). The main MD controls are
|
|
in [MOTION/MD](#CP2K_INPUT.MOTION.MD): [ENSEMBLE](#CP2K_INPUT.MOTION.MD.ENSEMBLE) selects the
|
|
propagator, [STEPS](#CP2K_INPUT.MOTION.MD.STEPS) or [MAX_STEPS](#CP2K_INPUT.MOTION.MD.MAX_STEPS)
|
|
sets the length of the run, [TIMESTEP](#CP2K_INPUT.MOTION.MD.TIMESTEP) sets the integration step,
|
|
and [TEMPERATURE](#CP2K_INPUT.MOTION.MD.TEMPERATURE) is used for velocity initialisation and as the
|
|
constant-temperature target.
|
|
|
|
A minimal fixed-energy MD block is:
|
|
|
|
```none
|
|
&GLOBAL
|
|
RUN_TYPE MD
|
|
PROJECT_NAME my_md
|
|
&END GLOBAL
|
|
|
|
&MOTION
|
|
&MD
|
|
ENSEMBLE NVE
|
|
STEPS 10000
|
|
TIMESTEP 0.5
|
|
TEMPERATURE 300
|
|
&END MD
|
|
&END MOTION
|
|
```
|
|
|
|
The force method is defined independently in [FORCE_EVAL](#CP2K_INPUT.FORCE_EVAL).
|
|
|
|
## Preliminary considerations
|
|
|
|
Universal to every atomistic simulation and every program, a number of crucial points must be
|
|
carefully considered before setting up a molecular dynamics task and investing copious amounts of
|
|
computational resources. As a starter, this section discusses preliminary factors in the choice of
|
|
the spatiotemporal scale of the trajectory, periodic boundary condition. force method, and the
|
|
initial structure.
|
|
|
|
### Space and time scale
|
|
|
|
Even when taking the ergodic hypothesis as granted, statistical analysis on target properties at
|
|
thermodynamic equilibrium has to be performed on top of sufficient sampling. The (auto)correlation
|
|
length and (auto)correlation time provide estimates for the space and time scale where measurements
|
|
of some property retain a memory of past states and are not fully statistically independent. It is
|
|
important to learn about their typical values in the same or similar systems, and take adequate
|
|
multiples as the size of the system and the length of the trajectory.
|
|
|
|
On the other hand, non-equilibrium irreversible processes such as phase transitions and chemical
|
|
reactions are also observable at some time and space resolution. Experimentally it is determined by
|
|
the sensitivity of instrumental characterization and analysis methods, with certain precise
|
|
definitions of the states before and after the process. Unfortunately, many experiments take place
|
|
in real life in a macroscopic time interval that exceeds the capability of simulation; for instance,
|
|
a chemical reaction taking days, hours, or even just seconds to happen may not be replicatable in
|
|
AIMD simulations with trajectory on the picosecond or nanosecond scale starting with only a bunch of
|
|
reactants randomly packed together, however thermodynamically favorable it is. Again, it is better
|
|
to survey literatures with relevant kinetic data and have a clear understanding of the typical free
|
|
energy barriers and reaction rates before proceeding to simulations. Even static thermochemistry
|
|
calculations for the profile of energy landscape via optimization of minima and transition states,
|
|
vibrational analysis and evaluation of single-point energy would be helpful. To simulate difficult
|
|
reactions by molecular dynamics in a short trajectory, advanced _enhanced sampling_ methods such as
|
|
[](./metadynamics) may be necessary.
|
|
|
|
### Periodic boundary condition
|
|
|
|
**Periodic boundary condition** ({term}`PBC`) may or may not be used in the molecular dynamics
|
|
simulation, and there are caveats for both ends.
|
|
|
|
On one hand, very small periodic cells for production MD should be avoided unless the finite-size
|
|
effects are known to be acceptable. Small cells produce artificial correlations through periodic
|
|
images, exaggerate statistical temperature and pressure fluctuations, and can make NPT cell dynamics
|
|
unstable or unphysical. Sometimes using a supercell of a crystalline structure is preferred if its
|
|
primitive cell is too small.
|
|
|
|
On the other hand, without PBC in MD, a common risk is that strong repulsion or very weak attraction
|
|
causes the system to expand and effectively diminishes desired interactions between molecules. A
|
|
possible remedy is to define an external potential or a constraint that act as a soft wall to
|
|
reflect or push stray molecules back to the center, but this is artificial and arbitrary.
|
|
|
|
### Force method
|
|
|
|
To propagate the trajectory in a molecular dynamics simulation, the energy and force is evaluated on
|
|
each timestep to provide acceleration via Newton's second law. The choice of the force method
|
|
determines the description of chemical bonding and/or weak interactions, the configuration space
|
|
that can be sampled, and the eventual computational cost. Careful selection of function forms and
|
|
parameters as well as thorough validation against the target property is vital to any application;
|
|
in particular, the part of "cross" interactions between two or more components described with more
|
|
than one unified force method requires very well-founded justification.
|
|
|
|
The strength and limitation of each force method is decided by design and parametrization. For
|
|
instance, classical force fields in molecular mechanics usually model chemical bonds by harmonic
|
|
potentials on the stretching, bending and rigid dihedral terms (and periodic torsion potentials on
|
|
the flexible dihedral terms). The simplicity of function forms allows for speedy evaluation and the
|
|
conformational fluctuation or conversion can be captured well, but the bonding pattern is fixed to
|
|
near equilibrium and bond breaking and forming in chemical reactions cannot be captured. To describe
|
|
the bond rearrangement and the underlying electronic structure, AIMD based on quantum chemical
|
|
methods becomes requisite even though it is slower and more costly. The middle grounds have recently
|
|
becoming filled with emerging methods like the machine-learning potentials.
|
|
|
|
### Initial structure
|
|
|
|
Because most of the points apply here as well, please first refer to the documentation about the
|
|
[starting structure and cell](../optimization/geometry_and_cell_opt.md#starting-structure-and-cell)
|
|
of a geometry optimization.
|
|
|
|
In general, start from a physically reasonable structure with sensible bond lengths, intermolecular
|
|
distances, density, and cell parameters. A majority of the force methods demonstrate extremely
|
|
strong repulsion at very small nuclei distances, and thus molecular dynamics simulation employing
|
|
these methods is not a reliable way to fix severe close contacts, unrealistic densities, or badly
|
|
prepared cells, because such problems can cause unstable forces, SCF failures, or immediate heating
|
|
and atom ejection.
|
|
|
|
In fact, when starting from scratch, a geometry optimization preceding molecular dynamics simulation
|
|
is highly recommended. During geometry optimization, the structure is relaxed and the maximum force
|
|
on atoms is significantly lowered, which puts an upper limit to the initial acceleration in the
|
|
subsequent molecular dynamics simulation and prevents rapid atomic motion and extreme temperature
|
|
rise. With electronic-structure methods, the geometry optimization also offers a chance to confirm
|
|
SCF convergence and estimate the time consumption on each step. The only "downside" is that the
|
|
temperature may start from or drop to a relatively low value at early simulation due to the small
|
|
forces and slow motion, and may take a little longer to heat up to the desired temperature; see the
|
|
section on equilibration below for how to address this.
|
|
|
|
## Initial velocities
|
|
|
|
If velocities are not provided by a restart file or an external trajectory, CP2K can initialise
|
|
atomic velocities from [TEMPERATURE](#CP2K_INPUT.MOTION.MD.TEMPERATURE). The
|
|
[INITIALIZATION_METHOD](#CP2K_INPUT.MOTION.MD.INITIALIZATION_METHOD) keyword controls how the
|
|
initial positions and velocities are generated.
|
|
|
|
For isolated molecules, clusters, slabs, or other systems where global translation or rotation is
|
|
not part of the intended dynamics, it can be useful to remove centre-of-mass translation and, when
|
|
meaningful, overall angular motion; see [COMVEL_TOL](#CP2K_INPUT.MOTION.MD.COMVEL_TOL),
|
|
[ANGVEL_TOL](#CP2K_INPUT.MOTION.MD.ANGVEL_TOL), [ANGVEL_ZERO](#CP2K_INPUT.MOTION.MD.ANGVEL_ZERO),
|
|
and related keywords. For periodic bulk systems, small total-momentum drift is usually less
|
|
important.
|
|
|
|
## Choosing an ensemble
|
|
|
|
The most common choices are `NVE`, `NVT`, `NPT_I`, `NPT_F`, and `LANGEVIN`.
|
|
|
|
- `NVE` is microcanonical dynamics. Use it to test the time step, force convergence, grid settings,
|
|
and extrapolation through energy conservation. It is also suitable for production when isolated
|
|
Hamiltonian dynamics is desired.
|
|
- `NVT` is canonical sampling at fixed cell. It is usually the most convenient ensemble for
|
|
equilibration and for production when the volume is known or fixed.
|
|
- `NPT_I` uses isotropic cell fluctuations. It is appropriate when only the cell volume should
|
|
fluctuate, for example for liquids, gases, or approximately isotropic solids.
|
|
- `NPT_F` uses a flexible cell. Use it when the cell shape and anisotropic stress relaxation are
|
|
part of the physical question, for example for solids or interfaces.
|
|
- `LANGEVIN` is stochastic constant-temperature dynamics. It is useful for robust equilibration,
|
|
dissipative dynamics, or models where a stochastic heat bath is intentional.
|
|
|
|
Other supported values of [ENSEMBLE](#CP2K_INPUT.MOTION.MD.ENSEMBLE) are more specialised: `NPE_I`,
|
|
`NPE_F`, `ISOKIN`, `REFTRAJ`, `MSST`, `MSST_DAMPED`, `HYDROSTATICSHOCK`, `NVT_ADIABATIC`, and
|
|
`NPT_IA`. See the input reference for details.
|
|
|
|
Note that NPT simulations are sensitive to system size and barostat settings; small cells can show
|
|
large pressure fluctuations and artificial cell oscillations. For small cells, consider fixed-cell
|
|
`NVT` after a separate cell optimisation, or use a larger supercell before production `NPT`.
|
|
|
|
## Thermostats
|
|
|
|
Constant-temperature ensembles use [MOTION/MD/THERMOSTAT](#CP2K_INPUT.MOTION.MD.THERMOSTAT). The
|
|
input keyword default for [TYPE](#CP2K_INPUT.MOTION.MD.THERMOSTAT.TYPE) is currently `NOSE`, but for
|
|
routine `NVT` equilibration and production `CSVR` is often the safer practical default.
|
|
|
|
- `CSVR`: recommended general-purpose choice. It gives canonical sampling through velocity rescaling
|
|
and is robust for both equilibration and production.
|
|
- `NOSE`: Nose-Hoover chain thermostat. It can be appropriate for well-equilibrated systems, but it
|
|
is less robust when the system is far from equilibrium or very small, and should not be the
|
|
default recommendation for new users.
|
|
- `GLE`: generalised Langevin thermostat. Use it for specialised coloured-noise applications or
|
|
workflows that need a fitted GLE kernel.
|
|
- `AD_LANGEVIN`: adaptive Langevin thermostat. Use it when adaptive stochastic thermostatting is
|
|
specifically desired.
|
|
|
|
A practical `NVT` setup is:
|
|
|
|
```none
|
|
&MOTION
|
|
&MD
|
|
ENSEMBLE NVT
|
|
TEMPERATURE 300
|
|
TIMESTEP 0.5
|
|
&THERMOSTAT
|
|
TYPE CSVR
|
|
&CSVR
|
|
TIMECON 100.0
|
|
&END CSVR
|
|
&END THERMOSTAT
|
|
&END MD
|
|
&END MOTION
|
|
```
|
|
|
|
The [CSVR/TIMECON](#CP2K_INPUT.MOTION.MD.THERMOSTAT.CSVR.TIMECON) (unit: fs) value controls the
|
|
coupling strength. Useful starting values are `50` for rapid heating or cooling, `100` as a simple
|
|
robust default, and `200` or larger for gentler production sampling after equilibration.
|
|
|
|
Do not use crude velocity rescaling as a production thermostat.
|
|
[TEMP_TOL](#CP2K_INPUT.MOTION.MD.TEMP_TOL) can trigger velocity rescaling when the instantaneous
|
|
temperature deviates from the target, but this keyword is obsolescent; a CSVR thermostat with a
|
|
short time constant is usually the better early- equilibration replacement.
|
|
|
|
## Barostats and NPT simulations
|
|
|
|
NPT simulations additionally use [MOTION/MD/BAROSTAT](#CP2K_INPUT.MOTION.MD.BAROSTAT). The pressure
|
|
target is set by [PRESSURE](#CP2K_INPUT.MOTION.MD.BAROSTAT.PRESSURE), and the barostat time scale by
|
|
[TIMECON](#CP2K_INPUT.MOTION.MD.BAROSTAT.TIMECON). For `NPT_F`,
|
|
[VIRIAL](#CP2K_INPUT.MOTION.MD.BAROSTAT.VIRIAL) can restrict which Cartesian components of the
|
|
virial are used for cell relaxation.
|
|
|
|
Use `NPT_I` when isotropic volume fluctuations are sufficient. Use `NPT_F` only when the cell shape
|
|
should respond to anisotropic stress. Full-cell NPT is powerful but can amplify problems from small
|
|
cells, poor initial structures, noisy stresses, or too aggressive barostat coupling. A robust
|
|
workflow is to equilibrate first in `NVT`, then run a short NPT test, inspect the cell trajectory
|
|
and pressure oscillations, and only then start production sampling. If the cell volume or shape
|
|
oscillates strongly, use a larger barostat time constant, a larger supercell, or fixed-cell `NVT` if
|
|
pressure sampling is not essential.
|
|
|
|
## Time step and validation
|
|
|
|
The time step must resolve the fastest relevant nuclear motion. For AIMD with light atoms, 0.5 ~ 1.0
|
|
fs is a common starting range. Use a smaller value for high temperature, weak bonds, reactive
|
|
events, poor starting structures, or hydrogen-rich systems. Constraints, deuteration, classical
|
|
force fields, or multiple-time-step schemes may allow larger time steps, but always validate the
|
|
choice.
|
|
|
|
A sensitive validation test is a short `NVE` trajectory. The total-energy oscillation and long-time
|
|
drift should be small relative to the kinetic energy or target temperature. Energy conservation
|
|
alone is not always sufficient for heterogeneous systems; also inspect the region or property of
|
|
interest when only part of the system matters.
|
|
|
|
## Electronic-structure settings for AIMD
|
|
|
|
Each AIMD step requires an electronic-structure calculation. Important Quickstep settings include
|
|
[EPS_SCF](#CP2K_INPUT.FORCE_EVAL.DFT.SCF.EPS_SCF),
|
|
[EPS_DEFAULT](#CP2K_INPUT.FORCE_EVAL.DFT.QS.EPS_DEFAULT), and the plane-wave grid parameters in
|
|
[MGRID](#CP2K_INPUT.FORCE_EVAL.DFT.MGRID), especially
|
|
[CUTOFF](#CP2K_INPUT.FORCE_EVAL.DFT.MGRID.CUTOFF) and
|
|
[REL_CUTOFF](#CP2K_INPUT.FORCE_EVAL.DFT.MGRID.REL_CUTOFF).
|
|
|
|
AIMD settings do not always need to match high-precision static energies or final property
|
|
calculations. For long trajectories, stable forces and negligible drift are often more important
|
|
than over-converging every SCF cycle. For example, if one element in your system use `CUTOFF 400` in
|
|
optimization and/or energy tasks, then in AIMD you can set to `CUTOFF 300`. However, too loose
|
|
settings can create noisy forces, poor energy conservation, artificial heating, or wrong dynamics.
|
|
|
|
## Extrapolation of the electronic initial guess
|
|
|
|
In a normal MD trajectory, consecutive geometries are close to each other. CP2K can use previous
|
|
electronic solutions to build a better initial guess for the next step through
|
|
[EXTRAPOLATION](#CP2K_INPUT.FORCE_EVAL.DFT.QS.EXTRAPOLATION) and
|
|
[EXTRAPOLATION_ORDER](#CP2K_INPUT.FORCE_EVAL.DFT.QS.EXTRAPOLATION_ORDER). A good extrapolation keeps
|
|
the electronic state continuous and usually reduces the number of SCF iterations at each MD step,
|
|
which is often crucial for efficiency.
|
|
|
|
For standard Born-Oppenheimer MD, `ASPC` is the default and generally the best first choice. It is
|
|
similar in spirit to `PS`, but is designed for MD stability rather than only initial-guess accuracy.
|
|
`EXTRAPOLATION_ORDER 3` is a good starting point for `ASPC` and `PS`.
|
|
|
|
`GEXT_PROJ` and `GEXT_PROJ_QTR` are also worth considering. They can use higher extrapolation
|
|
orders, typically 4 ~ 10. `GEXT_PROJ_QTR` is better suited for long-term dynamical stability in
|
|
principle.
|
|
|
|
## Equilibration
|
|
|
|
Equilibration should remove artefacts of the initial structure and velocity distribution before any
|
|
production statistics are collected. It does not have to be performed in `NVT`. A good equilibration
|
|
setup is usually the same as, or close to, the intended production ensemble: use `NVT` for
|
|
fixed-cell canonical sampling, `NPT_I` or `NPT_F` when pressure and cell relaxation are part of the
|
|
target workflow, and `LANGEVIN` when stochastic damping is desired. A typical protocol is:
|
|
|
|
- Prepare a reasonable starting structure;
|
|
- Set the target temperature directly for ordinary heating, or use staged heating/cooling when an
|
|
abrupt temperature change is likely to destabilise the trajectory or when the thermal path is
|
|
important;
|
|
- Equilibrate in the chosen target-like ensemble with suitable thermostat and, when needed, barostat
|
|
time constants;
|
|
- Continue with adjusted thermostat or barostat parameters for gentler production sampling;
|
|
- Discard the equilibration part before computing averages.
|
|
|
|
For heating with `CSVR`, a practical two-stage strategy is to use a relatively short thermostat time
|
|
constant first, for example `TIMECON 50`, to bring the system close to the target temperature
|
|
quickly, and then switch to a gentler production setting such as `TIMECON 200`. This is useful when
|
|
the initial and target temperatures are not too far apart and the structure is already reasonable,
|
|
but a short equilibration stage is still desired before collecting statistics.
|
|
|
|
If a separate equilibration stage is not necessary, or if a simple robust setup is preferred, one
|
|
can also run the whole trajectory with an intermediate coupling strength, for example `TIMECON 100`.
|
|
This is often sufficient for ordinary room-temperature or moderately high-temperature simulations,
|
|
and the equilibration and production parts may then differ only in which initial frames are
|
|
discarded from the analysis.
|
|
|
|
If the target temperature is very high, directly heating to that temperature can make the simulation
|
|
likely to crash. In such cases, staged heating is recommended: increase
|
|
[TEMPERATURE](#CP2K_INPUT.MOTION.MD.TEMPERATURE) through several short equilibration stages until
|
|
the final target temperature is reached. This is especially useful for AIMD at several thousand
|
|
kelvin, reactive systems, poor initial structures, or systems with close contacts. The thermostat
|
|
`TIMECON` still controls the coupling strength within each stage, but it does not replace the need
|
|
for a gradual temperature schedule when an abrupt jump would destabilise the trajectory.
|
|
|
|
For cooling or annealing, it is usually best to lower the target temperature in stages, especially
|
|
when the final structure depends on the cooling path. One-step cooling can also be used, but the
|
|
thermostat coupling should be weak enough, with a sufficiently large `TIMECON` so that the
|
|
temperature decreases slowly rather than being quenched abruptly. The appropriate schedule depends
|
|
on the system and on whether the goal is sampling, relaxation, or deliberate annealing.
|
|
|
|
For stochastic equilibration, use the `LANGEVIN` ensemble and adjust
|
|
[GAMMA](#CP2K_INPUT.MOTION.MD.LANGEVIN.GAMMA): smaller values are closer to NVE-like dynamics and
|
|
equilibrate more slowly; larger values thermostat more aggressively.
|
|
|
|
Temperature is an instantaneous kinetic estimator and is expected to fluctuate. A single snapshot at
|
|
the target temperature is not evidence of equilibration. Check structural, energetic, and
|
|
property-specific observables. For heterogeneous systems, do not rely only on total energy or global
|
|
temperature; also inspect the region of interest.
|
|
|
|
## Trajectories, energies, and restarts
|
|
|
|
The trajectory is controlled by [MOTION/PRINT/TRAJECTORY](#CP2K_INPUT.MOTION.PRINT.TRAJECTORY). By
|
|
default, positions are written to files such as `project-pos-1.xyz`, where `project` is the value of
|
|
[PROJECT_NAME](#CP2K_INPUT.GLOBAL.PROJECT_NAME). Velocities, forces, cell vectors, stresses, and
|
|
restart files are controlled by other print keys in [MOTION/PRINT](#CP2K_INPUT.MOTION.PRINT).
|
|
|
|
The file `project-1.ener` is often the first file to inspect. It contains columns such as
|
|
|
|
```none
|
|
md_step, time[fs], e_kin[hartree], temp[K], e_pot[hartree], e_tot[hartree], elapsed_time_per_step[s]
|
|
```
|
|
|
|
For thermostatted or barostatted simulations, also inspect the corresponding conserved quantity or
|
|
cell output when available. For production runs, write restart files frequently enough that the
|
|
trajectory can be continued without losing significant sampling time.
|
|
|
|
## Validation checklist
|
|
|
|
Before running a long production trajectory, it is suggested to check that:
|
|
|
|
- The planned length of trajectory and reserved computational time is long enough to overcome
|
|
(auto)correlations and/or observe phenomena;
|
|
- The force method and key parameters is validated on the particular system and is suitable for
|
|
describing the target property;
|
|
- The structure is physically reasonable and the shortest interatomic distances are sensible;
|
|
- The periodic cell is large enough for the target property;
|
|
- The SCF procedure converges reliably on representative snapshots;
|
|
- The extrapolation method reduces SCF iterations without causing instability;
|
|
- The time step gives acceptable energy conservation in a short test;
|
|
- Thermostat and barostat time constants do not dominate the physical dynamics of interest;
|
|
- NPT cell fluctuations are reasonable and not dominated by small-cell oscillations;
|
|
- Output frequencies are sufficient for the target analysis but not so high that I/O dominates.
|